Haier - Energy Saving

Page 7 of 11

Report No.: AHES230800110871

Energy consumption test

Test result: Test No.

Air conditioner

Test environment

Test result

Energy-saving effect

Fan number

Air volume (m 3 /h)

Test setting

Target average room temperature

Test condition

Area (m 2 )

Installation height of the indoor unit (m)

Energy consumption (kWh)

Energy wasting (kWh)

Energy wasting ratio (%) 1

Energy saving ratio (%) 2

1

4# (100% air volume)

670

1.220V, 50Hz 2.Mode: Cooling 3.Fan speed: High 4.Guide plate: Maximum position of air outlet 1.220V, 50Hz 2.Mode: Heating 3.Fan speed: High 4.Guide plate: Maximum position of air outlet

22°C

Indoor: 30°C/- Outdoor: 35°C/24°C

0.860

/

/

30.4

2

1# (85% air volume) 2# (80% air volume) 3# (65% air volume)

562

0.968

0.108

12.6

21.7

3

540

1.106

0.246

28.6

10.5

4

422

1.236

0.376

43.7

/

16.8

2.3

5

4# (100% air volume)

670

19°C

Indoor: 10°C/-

0.897

/

/

54.1

Outdoor: 2°C/1°C

6

1# (85% air volume) 2# (80% air volume) 3# (65% air volume)

562

0.928

0.031

3.5

52.6

7

540

1.582

0.685

76.4

19.1

8

422

1.956

1.059

118.1

/

Remark: 1. Energy wasting ratio (%) = (energy consumption (*#) - energy consumption (4#)) / energy consumption (4#) (*=1, 2 or 3) 2. Energy saving ratio (%) = (energy consumption (3#) - energy consumption (*#)) / energy consumption (3#) (*=1, 2 or 4)

TRF No. EEC_Protocol performance test A

Made with FlippingBook - professional solution for displaying marketing and sales documents online